- 
              GDFJ-311M SF6 Gas Decomposition Product TesterGDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product. 
- 
              GLF-314 SF6 Gas Infrared Imaging Leak DetectorThe SF6 infrared imaging leak detector is a non-contact gas imaging leak detection device that can detect possible gas leaks at several meters or tens of meters. It can quickly scan a large detection area and accurately find leaks in real time. The gas detection thermal imager can detect the leakage or unorganized emission of organic volatiles, and still has good performance even for very small gas leakage. The use of gas leakage detection is an efficient and reliable solution, which can detect the leakage of natural gas products in various links such as transportation, storage and production, so as to maximize safety and save costs. 
- 
              GDP-311IR SF6 Gas Purity Tester (IR Method)GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company. 
- 
              GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method)GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection. The perfect combination of high-quality dew point sensor and intelligent electronic control technology makes it successfully applied to accurate measurement of dew point under various environmental conditions. The dew point measurement is based on the principle of chilled mirror. The water vapor in the measured gas is condensed into water or frost on the mirror surface through semiconductor cold reactor cooling. When the two-phase equilibrium of water in the gas is reached, the temperature of the mirror surface is measured at this time, that is the dew point or frost point. Compared with other forms of dew point meter, the chilled mirror dew point meter measures the dew point temperature more accurately, and at the same time has the characteristics of good measurement repeatability, stable and reliable measurement results, and easy operation. GDP-713PM portable cooling method SF6 gas dew point meter is a standard instrument for humidity measurement in the fields of electric power, gas, meteorology, electronics, petroleum, chemical industry, measurement, etc. It is an ideal choice for establishing a humidity standard device. 
- 
              GDP-311CAW 3-in-1 SF6 Quality AnalyzerGDP-311PCAW SF6 gas quality analyzer is a portable device designed to measure SF6 gas purity, dew point, composition, CF4 content and air content. 
- 
              GDQH-31H Portable SF6 Gas Recovery DeviceGDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested. At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV. 
- 
              GDPDS-341 SF6 Electrical Insulation State Comprehensive AnalyzerAt present, the UHV voltage level of 110KV and above uses SF6 gas-insulated enclosed GIS as the main primary equipment of the substation, the evaluation of GIS internal insulation status is mainly achieved by partial discharge detection method and SF6 gas chemical analysis method at home and abroad. 
- 
              GDQH-601-50 SF6 Gas Recycling MachineThe model GDQH-601-50 is special machine of vacuumizing and filling device. It is suitable for SF6 electrical equipment, GIS manufacturer and research institute. 
- 
              GDSF-311WP SF6 Dew Point and Purity TesterGDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. 
- 
              GDQC-55A SF6 Gas Vacuuming and Filling MachineGDQC-55A SF6 Gas Vacuuming and Filling Machine is mainly used for vacuuming and filling SF6 gas insulated electrical equipment in the manufacturing, use and scientific research departments. It is suitable for SF6 electrical equipment, GIS manufacturer and research institute. 
- 
              GDJD-3A SF6 Gas Density Relay CalibratorGDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. 
- 
              GDSF-411CPD SF6 Gas Comprehensive AnalyzerGDSF-411CPD SF6 gas comprehensive analyzer is a portable device designed to measure SF6 gas dew point, purity and decomposition product. 
